C-Series Air-Hydraulic Press Control Packages

(standard packages)

DP = Pneumatic

(No Electricity Needed)

EDP = Electric

(120V Control Power Needed)

DP-1 or EDP-1 Control Package:

Basic two-hand non-tie control package. The operator initiates both actuators at the same time to advance the press stroke. Once the operator releases one of both actuators, the cylinder rod/ram returns to home position (Available Options & Add-on Features: DR, TD, PSRO, 24VDC, PLC, SLC, SS1122, E-LPT, SIG)

DP-1-NP or EDP-1-NP Control Package:

Two-hand non-tie down jog control package. The operator initiates both actuators at the same time to advance the press stroke. If the operator releases one of both actuators during the downward stroke, the cylinder rod/ram stops its downward motion. The operator can either proceed with the downward cycle by re-initiating the actuators until press force or stroke distance is achieved, or manually retract the cylinder rod/ram to home position by pressing the manual retract button. Standard with PSRO option. (Available Options & Add-On Features: DR, TD, 24VDC, PLC, SLC, SS1122, E-LPT, SIG)

DP-2 or EDP-2 Control Package:

Low force approach stroke with adjustable hydraulic intensified boost stroke. This package is beneficial for C-Series Press with additional (non-standard) stroke lengths. The operator initiates both actuators at the same time to advance the press stroke under a low force approach stroke. Once the adjustable limit switch is initiated, the control system shifts into a hydraulic intensified boost/power stroke (which can range from 0 to 6.0"). Once the operator release one or both actuators, the cylinder rod/ram returns to home position. (Available Options: DR,TD, PSRO, 24VDC, PLC, SLC, SS1122, E-LPT, SIG)

EDP-3 Control Package:

Muting/capture control package with adjustable (0 to 10 sec.) timer delay cylinder rod/ram return. The operator initiated both actuators at the same time to advance the press stroke. Once the cylinder rod/ram meets the work piece (closing the pinch point), an indicator turns on notifying the operator that they can remove their hands from the actuators. The cylinder rod/ram remains extended. The cylinder rod/ram automatically returns to home position once the timer is complete. Note: if the operator removes one or both hands from the actuator before the indicator turns on, the cylinder rod/ram returns to home position without starting the mute/capture sequence. Standard with TD option. (Available with DR, 24VDC, PLC, SLC, SS1122, E-LPT, SIG)

Available Control Options

  • DR = Distance Initiated w/Adjustable Timer Delay Ram Return
  • TD = Pressure Initiated w/Adjustable Timer Delay Ram Return
  • PSRO = Pressure Initiated Ram Return
  • AS = Dual Regulated System (Air Savings)

Add-On Features

  • 24VDC = 24VDC Control Circuits
  • PLC = Programmable Logic Controller
  • SLC = Safety Light Curtain with Guarding
  • SS1122 = Load Cell (Force) Monitoring
  • E-LPT = Linear (Distance) Position Monitoring
  • SIG = Both Force over Distance Monitoring (Signature)