C-Series 2.5 Ton to 15 Ton Air Over Oil Presses

Standard Control Packages

EDP = Electric Logic
(110v electricity required)

DP = Pneumatic Logic
(No electricity required)

EDP-1 or DP-1: Basic two-hand non-tie down control package with single regulator.

Operator initiates and maintains both actuators at the same time to advance the press stroke. Once the operator releases one or both actuators, the ram returns to home position.

EDP-AS-1 or DP-AS-1: Basic two-hand non-tie down control package with dual regulator (adjust retract pressure)
Operator initiates and maintains both actuators at the same time to advance the press stroke. Once the operator releases one or both actuators, the ram returns to home position.

EP-1-NP or DP-1-NP: Two-hand non-tie down control package with jog control.
Operator initiates and maintains both actuators at the same time to advance the press stroke. If the operator releases one of both actuators during the downward stroke, the ram stops downward motion. The operator can either proceed with the downward cycle by re-initiating the actuators until the auto ram return option is meet (see auto ram return options), or the operator can manually retract the ram to home position by pressing the manual ram return button (Note: includes P-TD or E-TD Pressure with Timer Return as the standard auto ram return option)

EDP-AS-2 or DP-AS-2: Two-hand non-tie down control package with low force approach stroke and an adjustable hydraulic intensified boost stroke.
Operator initiates and maintains both actuators at the same time to advance the press stroke under a low force approach stroke. Once the adjustable limit switch is met, the control system shifts into a hydraulic intensified boost/power stroke. Once the operator releases one or both actuators, the ram returns to home position

Auto Ram Return Options:

(Add to the above standard control packages – excluding the DP-1-NP or EDP-1-NP)

E = Electric Logic / P= Pneumatic Logic

E-TD or P-TD: Pressure with Timer Return
Pressure sensor initiates an adjustable press dwell timer which returns the ram

E-DR or P-DR: Distance with Timer Return
Distance sensor initiates and adjustable press dwell timer which returns the ram

E-PSRO or P-PSRO: Pressure Only Return
Pressure sensor only initiates the return of the ram

E-FI: Fault Circuit (only available in electric logic)
Fault indicator with reset for short stroke notification (press stroke did not complete the normal cycle). Pressure sensor initiates an adjustable press dwell timer which returns the ram. Also, includes illuminated manual reset indicator

E-FIRR: Ram Capture (only available in electric logic)
Pressure initiated ram capture (muting); allowing the operator to remove their hands from the actuators and an adjustable press dwell timer returns the ram. Complete with illuminated ram capture indicator and manual retract button

Other Available Options

(please consult factory)

▪ 24vDC Control Circuit ▪ Programmable Logic Controller (PLC) ▪ Emergency Stop Control Circuit ▪ Light Curtains and Guarding ▪ Rod End Load Cell ▪ Linear Position Transducer ▪ Press Force and Distance Monitoring ▪ Custom Designed Control Systems

***Note: all control packages are assembled complete with necessary F-R-L unit, air lock-out valve, flow control valve, directional valve and exhaust mufflers.