AP-Series Black & Webster Air Press 150 Lbs. to 1900 Lbs.

Standard Control Packages

EDP = Electric Logic
(110v electricity required)

DP = Pneumatic Logic
(No electricity required)

EDP-1 or DP-1: Basic two-hand non-tie down control package
Operator initiates and maintains both actuators at the same time to advance the press stroke. Once the operator releases one or both actuators, the ram returns to home position.

EP-1-NP or DP-1-NP: Two-hand non-tie down control package with jog control
(only available on the AP1900D Air Press)
Operator initiates and maintains both actuators at the same time to advance the press stroke. If the operator releases one of both actuators during the downward stroke, the ram stops downward motion. The operator can either proceed with the downward cycle by re-initiating the actuators until the auto ram return option is meet (see auto ram return options), or the operator can manually retract the ram to home position by pressing the manual ram return button (Note: includes P-TD1 or E-TD1 Pressure with Timer Return as the standard auto ram return option)

EDP-2-SA1: Modular (all in one) two-hand non-tie down unit with pressure initiated / adjustable timer delay ram return
(only available on the AP150 & AP400 Air Presses)
Operator initiates and maintains both actuators at the same time to advance the press stroke. Once pre-set pressure is achieved, an adjustable timer is initiated. Once the timer is complete, the ram retracts.

EDP-2-SA2: Modular (all in one) two-hand non-tie down unit with pressure initiated / adjustable timer delay ram return
(only available on the AP1200 & AP1900 Air Presses)
Operator initiates and maintains both actuators at the same time to advance the press stroke. Once pre-set pressure is achieved, an adjustable timer is initiated. Once the timer is complete, the ram retracts.

Auto Ram Return Options:

(Add to the above standard control packages – excluding the DP-1-NP or EDP-1-NP)

E = Electric Logic / P= Pneumatic Logic

E-TD1 or P-TD1: Pressure with Timer Return
Pressure sensor initiates an adjustable press dwell timer which returns the ram

E-PSR1 or P-PSR1: Pressure Only Return
Pressure sensor only initiates the return of the ram

***Note: all control packages are assembled complete with necessary filter and regulator unit, air lock-out valve, flow control valve, directional valve and exhaust mufflers.